PRODUCTS
ExactCables is a Pioneer Manufacturer with over 12 Years of Experience.

FPLR Fire Alarm Cable


The UL listed FPLR type shielded power limited fire alarm riser cable is suitable to be use in a vertical runs in signaling & fire alarm system. It works in high temperature levels. This cable is constructed with FR-PVC insulation and outer jacket with aluminum and PE tape shielding that meets UL 1666 specications. This cable complies with VW - 1 Flame Test requirements in ANSI/UL 1581.

Tested as per ANSI/UL 1666 for ame propagation height of electrical and optical - Fibre Cables Installed Vertically in Shafts.

The UL listed FPLR type shielded power limited fire alarm riser cable is suitable to be use in a vertical runs in signaling & fire alarm system. It works in high temperature levels. This cable is constructed with FR-PVC insulation and outer jacket with aluminum and PE tape shielding that meets UL 1666 specications. This cable complies with VW - 1 Flame Test requirements in ANSI/UL 1581.

Tested as per ANSI/UL 1666 for ame propagation height of electrical and optical - Fibre Cables Installed Vertically in Shafts.

· Certificate: UL Listed

· Standard: UL 1424 / NEC Article 760

· Temperature: -20°C to 105°C

· Voltage: 300 V

· Compliance: FPLR/CMR/CL3R, flame test UL 1666   /    FPL/CM/CMG/CL3, flame test UL 1685

· Application: Riser fire alarm wiring   /    General purpose fire alarm wiring

 

Main parts and material

Conductor Multiconductor, solid or stranded bare copper Insulation (Dielectric) Flame retardant PVC, color red & black (2C)
Shield Aluminum mylar tape Drain wire (Earth wire) Tinned copper, 7 x stranded 0.2mm dia.
Rip cord 150D Nylon, white Jacket Flame retardant PVC, color red

 

Available size (Solid conductor)

Size Conductor Max DCR Insulation THK Jacket THK Nom. Cable OD Ref. No.
Type Nominal dia (mm) Section (mm2) 20°C, Ω/km mm mm mm
22 AWG x 4C Solid 0.64 x 4C 0.32 59.1 0.26 0.6 3.8 C0301
18 AWG x 2C Solid 1.02 x 2C 0.82 21.4 0.26 0.6 5.2 C0302
18 AWG x 4C Solid 1.02 x 4C 0.82 21.4 0.26 0.7 6.2 C0303
16 AWG x 2C Solid 1.29 x 2C 1.31 13.5 0.26 0.7 5.8 C0304
16 AWG x 4C Solid 1.29 x 4C 1.31 13.5 0.26 0.7 6.8 C0305
14 AWG x 2C Solid 1.63 x 2C 2.08 8.45 0.26 0.7 6.9 C0306
12 AWG x 2C Solid 2.05 x 2C 3.31 5.31 0.26 0.7 8 C0307

 

Available size (Stranded conductor)

Size Conductor Max DCR Insulation THK Jacket THK Nom. Cable OD Ref. No.
Type Nominal dia (mm) Section (mm2) 20°C, Ω/km mm mm mm
22 AWG x 4C 7 stranded 0.73 x 4C 0.32, min 55.4 0.26 0.6 4.6 C0311
18 AWG x 2C 7 stranded 1.16 x 2C 0.81, min 21.9 0.26 0.6 5.4 C0312
18 AWG x 4C 7 stranded 1.16 x 4C 0.81, min 21.9 0.26 0.7 6.5 C0313
16 AWG x 2C 7 stranded 1.46 x 2C 1.28, min 13.7 0.26 0.7 6.7 C0314
16 AWG x 4C 7 stranded 1.46 x 4C 1.28, min 13.7 0.26 0.7 7.2 C0315
14 AWG x 2C 7 stranded 1.85 x 2C 2.04, min 8.6 0.26 0.7 7.5 C0316
12 AWG x 2C 7 stranded 2.32 x 2C 3.26, min 5.41 0.26 0.7 8.5 C0317

· Certificate: UL Listed

· Standard: UL 1424 / NEC Article 760

· Temperature: -20°C to 105°C

· Voltage: 300 V

· Compliance: FPLR/CMR/CL3R, flame test UL 1666   /    FPL/CM/CMG/CL3, flame test UL 1685

· Application: Riser fire alarm wiring   /    General purpose fire alarm wiring

 

Main parts and material

Conductor Multiconductor, solid or stranded bare copper Insulation (Dielectric) Flame retardant PVC, color red & black (2C)
Shield Aluminum mylar tape Drain wire (Earth wire) Tinned copper, 7 x stranded 0.2mm dia.
Rip cord 150D Nylon, white Jacket Flame retardant PVC, color red

 

Available size (Solid conductor)

Size Conductor Max DCR Insulation THK Jacket THK Nom. Cable OD Ref. No.
Type Nominal dia (mm) Section (mm2) 20°C, Ω/km mm mm mm
22 AWG x 4C Solid 0.64 x 4C 0.32 59.1 0.26 0.6 3.8 C0301
18 AWG x 2C Solid 1.02 x 2C 0.82 21.4 0.26 0.6 5.2 C0302
18 AWG x 4C Solid 1.02 x 4C 0.82 21.4 0.26 0.7 6.2 C0303
16 AWG x 2C Solid 1.29 x 2C 1.31 13.5 0.26 0.7 5.8 C0304
16 AWG x 4C Solid 1.29 x 4C 1.31 13.5 0.26 0.7 6.8 C0305
14 AWG x 2C Solid 1.63 x 2C 2.08 8.45 0.26 0.7 6.9 C0306
12 AWG x 2C Solid 2.05 x 2C 3.31 5.31 0.26 0.7 8 C0307

 

Available size (Stranded conductor)

Size Conductor Max DCR Insulation THK Jacket THK Nom. Cable OD Ref. No.
Type Nominal dia (mm) Section (mm2) 20°C, Ω/km mm mm mm
22 AWG x 4C 7 stranded 0.73 x 4C 0.32, min 55.4 0.26 0.6 4.6 C0311
18 AWG x 2C 7 stranded 1.16 x 2C 0.81, min 21.9 0.26 0.6 5.4 C0312
18 AWG x 4C 7 stranded 1.16 x 4C 0.81, min 21.9 0.26 0.7 6.5 C0313
16 AWG x 2C 7 stranded 1.46 x 2C 1.28, min 13.7 0.26 0.7 6.7 C0314
16 AWG x 4C 7 stranded 1.46 x 4C 1.28, min 13.7 0.26 0.7 7.2 C0315
14 AWG x 2C 7 stranded 1.85 x 2C 2.04, min 8.6 0.26 0.7 7.5 C0316
12 AWG x 2C 7 stranded 2.32 x 2C 3.26, min 5.41 0.26 0.7 8.5 C0317
Previous: No more data
* Name
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
* Email
Address
* Message